• Welcome to IPTV Community! You need login/register in-order to access forum without restriction.

Search results

  1. K

    MAG 250 Technical Issues

    Did you install the drivers that was in the folder ? CDM+v2.12.14+WHQL+Certified
  2. K

    MAG 250 Technical Issues

    If it says micro connect in device manager then it is programmed , do you see that under com port and usb settings ?
  3. K

    MAG 250 Technical Issues

    The St Micro apps are 32 bit applications , not designed to work on a 64 bit system. best you use XP or win7 32 bit
  4. K

    MAG 250 Technical Issues

    1. The power should be connected to the mag box 2. Hard to say if they are in the correct place as you have not shown the link from PCB to MAG250 3. PCB should have the 5v jumper set. Looking at your screenshots it looks like you have not programmed the board with the .EPT file as it does...
  5. K

    MAG 250 Technical Issues

    The guide is for clones , but should work on genuine bricked boxes as well. You can normally tell the clone from the mac address , as it should/could have the same numbering as the serial # On the original boxes it looks like there is a 2nd copy of the bootloader on the 1Mb NOR flash , now...
  6. K

    MAG 250 Technical Issues

    @Camdtv .. apologies on your first pics the one side will all be odd numbers and the other side will be evens 1.3.5.7.9.11.13.15.17.19 2.4..6.8.10.12.14.16.18.20 so the ones you refer to as 20,19,18 are actually 20.18.16 which is your TX,RX &Gnd on the opposite side will be the JTAG side...
  7. K

    MAG 250 Technical Issues

    @Camdtv - Yes your numbering is correct. @davetv - There is no 64bit version. @sandy 22 & @Mikeios If your server is updating your box , you should be able to see it updating the minute you connect to your server (If your server does this)
  8. K

    MAG 250 Technical Issues

    Well the standard seems to be 1-3 days , so if it lasts longer than that you should be fine.
  9. K

    MAG 250 Technical Issues

    Make sure you are using a decent USB stick , in the mag250 folder on the usb stick do you have the bootstrap as well as the firmware image ?
  10. K

    MAG 250 Technical Issues

    That programmer should work as it accepts JTAG and UART , Personally don't see the need for the connector and ribbon cable unless you are doing multiple boxes , would personally just solder a few leads on to both sides...
  11. K

    MAG 250 Technical Issues

    Yeah , load the R19 public image first , then it should accept this one that i uploaded, that is how i did it.
  12. K

    MAG 250 Technical Issues

    Just need to wait and see now... the process i followed for these devices was similar to yours , i revived the box then updated to the R19 public image , but then i updated to this one , and the box has remained stable.
  13. K

    MAG 250 Technical Issues

    Revive the box and flash with this firmware image and let me know if the box remains stable. https://www.sendspace.com/file/9klzuo
  14. K

    MAG 250 Technical Issues

    You need to use a hex editor not notepad.
  15. K

    MAG 250 Technical Issues

    The problem you have is your are only fixing the bootloader , you need to reflash the older firmware that does not contain the clone killer image.
  16. K

    MAG 250 Technical Issues

    That should not matter once you load the EPT file from the folder ,you will then re-program your device to what it needs to be.
  17. K

    MAG 250 Technical Issues

    Gents , this is a very easy mode to do , the ribbon cable connector is not essential , you can just solder your needed wires to the programmer and pin-outs on the board, the rest of the Jtag and serial method is pretty straight forward.